02 · SAW flux · PWL
PWL 5101
Acidic · basicity 0.5 – 0.8
Agglomerated
Agglomerated
Aluminium-titanium type acidic flux (former product name OP-185). With EL8 and EM12K for low carbon and some low alloy steels — boilers, pressure vessels, ships. Specified for high-speed welding of power plant boiler water walls, at speeds up to 70 m/h. AC or DC; wire positive on DC.
Classification
AWS A5.17 F7AZ-EL8 · F7AZ-EM12K
All weld metal — flux / wire combination, as welded
| Classification | UTS, MPa | YS 0.2 %, MPa | Elongation, % | CVN, J |
|---|---|---|---|---|
| F7AZ-EL8 | — | > 330 | 27 | > 27 |
| F7AZ-EM12K | 480 – 600 | > 400 | 28 | > 27 |
Swipe sideways for all columns →
Major constituents of flux, %
| SiO₂ + TiO₂ | CaO + MgO | Al₂O₃ + MnO | CaF₂ | S | P | Grain size | |
|---|---|---|---|---|---|---|---|
| Range | 25 – 35 | — | 50 – 60 | 3 – 10 | < 0.06 | < 0.08 | 10 – 60 |
Swipe sideways for all columns →
Wires to use with PWL 5101
Suited to: Boiler water walls at high speed · boilers, pressure vessels, ships.
Packing and storage
25 kg bag, paper with HDPE liner · bulk 25 – 1000 kg in big-bags or steel drums · pallets up to 1000 kg, shrink wrapped. Opened bags or drums: keep at 250 ± 25 °C before use. Storage & handling →
Other PWL fluxes