Specification — the value specified for the gradeTypical — typical values for the grade, as published by PWL
Chemical composition of wire electrode, %
| C | Mn | Si | S | P | Cu coating % | |
|---|---|---|---|---|---|---|
| Specification | 0.04 – 0.14 | 0.25 – 0.60 | 0.10 max | 0.03 max | 0.03 max | 0.35 max |
| Typical | 0.06 | 0.35 | 0.04 | 0.015 | 0.022 | 0.09 |
Swipe sideways for all columns →
Weld metal with PWL fluxes
No flux–wire classification is published for EL12 in the catalogue. For a combination not shown, please contact us.
Packing
Layer-wound ring 25 – 30 kg · flanged bobbin 250 kg · steel or cardboard drum 300 · 500 · 650 kg. Packaging specification →
Other PWL SAW wires