Specification — the value specified for the gradeTypical — typical values for the grade, as published by PWL
Chemical composition of wire electrode, %
| C | Mn | Si | S | P | Ni | Mo | Cu coating % | |
|---|---|---|---|---|---|---|---|---|
| Specification | 0.10 – 0.18 | 1.50 – 2.40 | 0.30 max | 0.025 max | 0.025 max | 0.70 – 1.10 | 0.40 – 0.65 | 0.35 max |
| Typical | 0.15 | 2.10 | 0.22 | — | — | 1.00 | 0.54 | 0.10 |
Swipe sideways for all columns →
Weld metal with PWL fluxes
No flux–wire classification is published for EF3 in the catalogue. For a combination not shown, please contact us.
Packing
Layer-wound ring 25 – 30 kg · flanged bobbin 250 kg · steel or cardboard drum 300 · 500 · 650 kg. Packaging specification →
Other PWL SAW wires